Converting a tower model to a rack model
Figure 374: Securing the accessible drive cage (B)
Ê Carefully turn the server upside down.
I
At least two people are needed to turn over a fully equipped server.
Remove HDDs and PSUs in order to facilitate the task.
Ê Secure the accessible drive cage with the two screws (see circles) to the
bottom side of the server.
I
Note the correct screw positions: The screw hole on the right that has
been used in the tower configuration remains empty.
Ê Install the front panel module as described in section
panel module" on page
Ê If applicable, install all accessible drives as described in section
an accessible drive" on page
Ê If applicable, install an HDD extension box as described in section
extension boxes" on page
Preparing the intrusion switch
Ê Remove the intrusion switch module as described in section
intrusion switch cable" on page
Ê Attach a rubber bumper (C26192-Y26-C43) to the front intrusion switch and
reinstall the intrusion switch module as described in section
intrusion switch cable" on page