Ê Lower the system board carefully into the chassis.
Ê Adjust the system board (orange circles in
centering bolts).
Ê Fasten the system board with the 10 screws (see
Ê Insert the crossbar and fasten it with the five screws (see
page
486).
Ê Remove the CPU from the defective system board as described in section
"Removing the CPU" on page
Ê Remove the protective plastic cover from the CPU socket of the new system
board and fit it onto the socket of the defective system board which will be
sent back to spares.
I
Returned system boards without this cover probably have to be
scrapped.
Ê Install the CPU on the new system board as described in section
the CPU" on page
Ê Reconnect all cables to the system board:
– Front panel cable
– Front USB cable
– Power cable(s) for HDD backplane(s)
– SATA cable(s) for HDD backplane(s)
– SATA cable for ODD (if applicable)
I
Loop back the SATA ODD cable and route it along the crossbar as
shown in
– Power cable for ODD (if applicable)
– Front VGA cable (if applicable)
– OOB cable (if applicable)
2
– I
C bus cable (if applicable)
For the cable plan see section
TX2560 M2 / RX2560 M2
382.
383.
figure 294 on page
"Cabling plans" on page
Upgrade and Maintenance Manual
System board and components
figure 362 on page 487
figure 362 on page
400.
512.
show the
487).
figure 361 on
"Installing
489