Removing A 3.5-Inch Hdd Module; Installing A 3.5-Inch Hdd Dummy Module - Fujitsu PRIMERGY RX2560 M2 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2560 M2:
Table of Contents

Advertisement

For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê When working on a tower server, open the HDD bay cover as described in
section
"Removing accessible drive and HDD bay covers" on page

7.3.10.2 Removing a 3.5-inch HDD module

Ê Pinch the green locking clips and open the locking lever (see
page
219).
Ê Pull the HDD module out a few centimeters.
Ê Wait about 30 seconds to allow the HDD to spin down.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê Pull the HDD module completely out of its bay.

7.3.10.3 Installing a 3.5-inch HDD dummy module

V
CAUTION!
If the removed HDD module is not replaced immediately, always replace
a dummy module into the unused HDD bay to comply with applicable
EMC regulations and satisfy cooling requirements.
Figure 135: Installing a 3.5-inch HDD dummy module
Ê Push the dummy module into the empty bay until it engages.
TX2560 M2 / RX2560 M2
Hard disk drive (HDD) / solid state drive (SSD)
Upgrade and Maintenance Manual
71.