Summary of Contents for Olympus fsx100

  • Page 2: Safety Precautions

    Introduction SAFETY PRECAUTIONS During observation and acquisition, the cover is kept closed to avoid the risk on the user. However, when placing or replacement, the cover should be opened so care is required in these operations. Caution against high temperature This section accommodates the light source bulb and may become hot.
  • Page 3: Open Button

    Main Controls Controrls Main switch Do not set the main switch to OFF for at : ON least 3 minutes after setting : OFF the sub-switch to OFF to allow the bulb to cool down. Cover Close lever Push down to close the cover.
  • Page 4 Observation/Acquisition Flow This section describes the basic operation fl ow in sequence together with the monitor screen displays. Selecting the Starting the Placing the Observation/ System Specimen Acquisition Methods p. 6 p. 7 p. 8...
  • Page 5 CAUTION The description in this section assumes that the following preparation work has been completed. ・ The cables are connected properly. ・ The software has been installed. ・ The lamp is attached. (For the operating procedures for the above, refer to the Instruction Manual [Hardware].
  • Page 6: Starting The System

    Observation/Acquisition Flow 1. Starting the System Set the main switch to “ l ” (ON). Push the sub switch to turn it on. Set the main switches of the computer and monitor to ON. Log on Windows Vista with your own user ID.
  • Page 7: Placing The Specimen

    2. Placing the Specimen The specimen can be placed in position when the instruction to place the specimen is displayed. Push down the open button open the cover and place the specimen. Slide glass specimen Push in the lock lever toward the left and hold it in the pushed-in position.
  • Page 8: Start Button

    Observation/Acquisition Flow 3. Selecting the Observation/Acquisition Methods Select the observation method. Fluorescence & Phase contrast observation / Phase contrast observation / Bright Field observation Select the acquisition method. Single / Time-Lapse / Z-Stack / Stitching (Scheduled to be available in March 2009) Select the fl...
  • Page 9 4. Observation/Acquisition Procedure Locate the observation target fi rst. Move the observation position (with drag & drop) to locate the observation target. Click on to go to the next screen. See next page for the operation guide display. Tightly target at the observation area in the macro image.
  • Page 10 Observation/Acquisition Flow 5. Operation Guide Display The operation guide shows the basic procedure for completing acquisition with the selected observation/ acquisition methods. Click to view the description text. Description text. Click to view the one-point tip. Click to go to the next screen. The Online Help gives more detailed explanations.
  • Page 11 6. Trying to Expand the Scope of Aquisition Features for trying to expand the range of acquisition: Z-Stack acquisition Fluorescence multi acquisition Bright Field acquisition Phase Contrast acquisition Time-Lapse acquisition This unit incorporates more other functions. For details, please refer to the separate Instruction Manual [Hardware] as well as the Operation Guide/ Online Help for the FSX-BSW Software.