Commissioning
6.1 Typical connection modes

Typical connection mode 6 (C06)

Description:
1. In LOC mode, motor start/stop, rotation direction and speed can be controlled via the
2. In REM mode, motor start/stop can be controlled via an external signal source connected
The DIP-switch settings
DIP-switch (AO): Depends on external RPM Meter
DIP-switch (AI): The DIP-switch setting in this application is inactive.
48
operator panel.
to DI1, motor set frequency via external signal sources connected to DI2 and DI3. When
DI2 is selected, you can change the motor set frequency with P1002 in the "Operation mode
⑤ - Access all the parameters (Page 71)" mode. When DI3 is selected, you can change
the motor set frequency with P1003 in the " Operation mode ⑤ - Access all the
parameters (Page 71) " mode. If both DI2 and DI3 are selected, the motor set frequency
is the sum of the value of P1002 and the value of P1003.
3 AC 400 V
L1
L2
L3
PE
L2
L3
PE L1
SINAMICS V10 Inverter
U V
W
M
3~
Factory defaut setting:
Factory defaut setting:
Lit while inverter running or alarm
Dim while inverter fault
Inverter running: Lamp ON
Dim while inverter fault
Inverter in any other status: Lamp OFF
Figure 6-6
Typical connection mode 6 (C06)
Fuse
Contactor
5
6
7
8
+24V
0V
DI1
DI2
Digital Input
AO
(mA)
Digital Output
DO1 DO1
1
2
N
L
220 AC Supply
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
Connection macro: C06
9
16
13
14
15
DI3
AI1- AI1+ AO1+
0V
+10V
Analog Input/Analog Output
I
I
U
U
AI
AO
AI
(V)
(mA)
(V)
DIP-switches
RS-485
Com A Com B
Operator Panel
RPM Meter
N
18
17
AO1-
P6V5 M
SINAMICS V10