Vulcan-Hart ML-126743 Service Manual page 64

Vc4e & vc6e series full size electric convection ovens
Hide thumbs Also See for ML-126743:
Table of Contents

Advertisement

VC4E & VC6E Series Full Size Electric Convection Ovens - TROUBLESHOOTING
CODE & PROBLEM
Er07 - Zone 1 A/D overflow error
Er10 - Stack overflow error
Er11 - Open sensor error
Er12 - Shorted sensor
1
Should only see when a new EPROM is installed and powered for the first time.
F25105 Rev. B (0217)
PROBABLE CAUSE
Open sensor
Microprocessor malfunction
Open sensor
Incorrect sensor type
Measuring temperature outside
the sensor range
Page 64 of 64
SOLUTION
Check the InP1 setup
parameter. Verify it matches
your sensor.
Check sensor and connections
for a reversed or open sensor. If
the condition causing the error is
resolved, the error will clear.
Cycle power
Check sensor and connections
for a reversed or open sensor
Check the InP1 setup
parameter. Verify it matches
your sensor.
Check sensor and connections
for a reversed or open sensor
Check the InP1 setup
parameter. Verify it matches
your sensor.
Check sensor and connections
for a reversed or open sensor

Hide quick links: