VC4E & VC6E Series Full Size Electric Convection Ovens - REMOVAL AND REPLACEMENT OF PARTS
2.
Reverse procedure to install.
DOOR CATCH ROLLER ASSEMBLY
(INDEPENDENT DOORS)
NOTE: For units with serial number starting with 48
made before 8/13/07 and serial number starting with
54 made before 8/27/07.
electrical power to the machine and
follow lockout / tagout procedures.
There may be multiple circuits. Be sure
all circuits are disconnected.
1.
Remove the top front cover as outlined under
COVERS AND PANELS.
2.
Remove the catch roller assembly.
Fig. 29
3.
Reverse procedure to install.
4.
Adjust the catch roller as outlined under DOOR
CATCH (ROLLER) ADJUSTMENT
(INDEPENDENT DOORS) in SERVICE
PROCEDURES AND ADJUSTMENTS.
Disconnect the
Page 17 of 64

MECHANICAL (KX) THERMOSTAT

electrical power to the machine and
follow lockout / tagout procedures.
There may be multiple circuits. Be sure
all circuits are disconnected.
1.
Remove the racks and right rack support.
2.
Remove the thermostat knob and mounting
screws from the control panel and then remove
the control panel.
3.
Remove the probe guard from the oven cavity
wall.
Fig. 30
NOTE: When installing probe guard, the probe should
not extend beyond the guard.
4.
Remove the thermostat bulb from the oven cavity
by pushing it through the oven wall and into the
control panel area.
NOTE: The hole in the oven cavity wall does not line
up straight with the oven cavity outer shell, therefore
the probe must be removed at an angle.
5.
Reverse the procedure to install.
6.
Adjust the thermostat as outlined under
MECHANICAL (KX) THERMOSTAT
CALIBRATION in SERVICE PROCEDURES
AND ADJUSTMENTS.

HIGH LIMIT THERMOSTAT

electrical power to the machine and
follow lockout / tagout procedures.
There may be multiple circuits. Be sure
all circuits are disconnected.
1.
Take out racks from the oven.
2.
Remove the high limit thermostat cover/mounting
plate from inside the oven cavity at the top.
Disconnect the
Disconnect the
F25105 Rev. B (0217)