5 UTILITY PACKAGE (GX Configurator-TC)

5 UTILITY PACKAGE (GX Configurator-TC)

5.1 Utility Package Functions

Table 5.1 Utility Package (GX Configurator-TC) Function List
Function
(1) Make initial setting for operating the temperature control module channel-by-channel.
5
Initial setting
(2) The initially set data are registered to the PLC CPU parameters, and when the PLC CPU is set
(1) Set the automatically refreshed temperature control module buffer memory channel-by-channel.
Automatic refresh
(2) The values stored in the temperature control module buffer memory where automatic refresh
5 - 1
Table 5.1 shows a list of the utility package functions.
Set the values of the items which require initial setting.
•CH
Input Range
•CH
Target Value Setting(SV)
•CH
Proportion(P) Setting
•CH
Integral Time(I) Setting
•CH
Differential Time(D) Setting
•CH
Output Control Cycle Setting
•CH
Control Response Parameter
•CH
Stop Mode Setting
•PID Continue Flag
•CH
Warning1 Mode Setting
•CH
Warning Setting Value1
•CH
Warning 2 Mode Setting
•CH
Warning Setting Value2
•CH
Warning 3 Mode Setting
•CH
Warning Setting Value3
•CH
Warning 4 Mode Setting
•CH
Warning Setting Value4
•Warning Non Sensitive Zone Setting
•Warning Delay Count
•CH
Loop Down Detect Decision Time
•CH
Loop Down Detect Dead Band
•CH
Heater Down Warning Setting
•Heater Down/OFF Time Abnormal Current
Detect Delay Count
to the RUN mode, they are written to the temperature control module automatically.
•Data Write Error Code
•CH
Measured Temperature Value(PV)
•CH
Operation Level(MV)
•CH
Target Value Setting(SV)
•CH
Transistor Output Flag
•CH
Occurred Warning Content
•CH
Warning Setting Value1
setting was made are automatically read when the END instruction of the PLC CPU is executed.
Description
•Heater Down Correcttion Function Select
•CT Monitor Format Change
•CT
Channel Layout Setting
•CT
CT Select
•CT
Standard Heater Current Value
•CH
Upper Limit Setting Limiter
•CH
Lower Limit Setting Limiter
•CH
Forward/Reverse Operation Setting
•CH
Chage Rate Limiter Setting
•CH
Sensor Correction Value Setting
•CH
Temporary Delay Digital Filter Setting
•CH
Upper Limit Output Limiter
•CH
Lower Limit Output Limiter
•CH
Output Change Level Limiter
•CH
Sensor Adjustment(NonSensitive)Setting
•CH
AT Bias
•CH
Unused Channel Setting
•Transistor ON Time Output Delay Monitor Setting
•Operation Level Resolution Change
•Temperaure Rise Complete Range Setting
•Temperature Rise Complete Sock Time Setting
•CH
Warning Setting Value2
•CH
Warning Setting Value3
•CH
Warning Setting Value4
•CH
Heater Down Warning Setting
•CH
Measured Heater Current Value
•CH
Operation Level
•CH
Temperature Rise Decision Flag
MELSEC-Q
Reference
section
Section 5.4
Section 5.5
5 - 1