Conformation To The Emc Directive And Low Voltage Instruction - Mitsubishi Electric MELSECSystem Q User Manual

Q64tctt;q64tcttbw; q64tcrt;q64tcrtbw
Table of Contents

Advertisement

Conformation to the EMC Directive and Low Voltage Instruction

A - 9
For details on making Mitsubishi PLC conform to the EMC directive and low voltage
instruction when installing it in your product, please see Chapter 3, "EMC Directive
and Low Voltage Instruction" of the User's Manual (Hardware) of the PLC CPU to
use.
The CE logo is printed on the rating plate on the main body of the PLC that conforms
to the EMC directive and low voltage instruction.
The following wiring is required for conformance of this product with the EMC
Directive and Low Voltage Directive.
(1) Use shielded cables for all external wiring and use the AD75CK cable clamp to
ground this product to an enclosure.
Inside control box
20cm (7.88 inch) to
30cm (11.82 inch)
(2) Using the AD75CK, you can tie four cables of about 7mm outside diameter
together for grounding.
(3) The following number of AD75CKs will be needed.
(Assuming that 7mm-diameter cables are used for all wiring)
Number of AD75CKs needed
Number of CT
channels used
AD75CK
Number of channels used
1
2
0
1
1
1
1
2
2
1
2
3
2
2
4
2
2
5
2
3
6
2
3
7
3
3
8
3
3
Strip the sheath.
3
4
2
2
2
3
2
3
3
3
3
3
3
4
3
4
4
4
4
4
A - 9

Advertisement

Table of Contents
loading

Table of Contents