Deutz TCD3.6 Engine Fault Codes
SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
175
0
Oil temperature; out of range, system reaction initiated
1
Physical range check low for oil temperature
2
Oil temperature; plausibility error
3
Sensor error oil temperature; signal range check high
4
Sensor error oil temperature; signal range check low
190
0
Engine speed above warning threshold (FOC-Level 1)
2
Offset angle between crank- and camshaft sensor is too large
8
Speed detection; out of range, signal disrupted
11
Engine speed above warning threshold (FOC-Level 2)
12
Speed detection; out of range, signal disrupted
14
Speed detection; out of range, signal disrupted
411
0
Physical range check high for differential pressure Venturiunit (EGR)
1
Physical range check low for differential pressure Venturiunit (EGR)
3
Sensor error differential pressure Venturiunit (EGR); signal range check high
4
Physical range check low for EGR differential pressure
Sensor error differential pressure Venturiunit (EGR); signal range check low
412
3
Sensor error EGR cooler downstream temperature; signal range check high
4
Sensor error EGR cooler downstream temperature; signal range check low
520
9
Timeout Error of CAN-Receive-Frame TSC1TR; Setpoint
597
2
Break lever mainswitch and break lever redundancyswitch status not plausible
624
3
SVS lamp; short circuit to battery
4
SVS lamp; short circuit to ground
5
SVS lamp; open load
12
SVS lamp; powerstage over temperature
630
12
Access error EEPROM
639
14
CAN-Bus 0 "BusOff-Status"
68
GTH-844