Horizontal Installation - Goodman ACS series Service Instructions Manual

80%, 90%, 95%
Table of Contents

Advertisement

ACCESSORIES
CONCENTRIC VENT CONVERSION KIT
The DCVK-20 (2") or the DCVK-
30 (3") is a new concentric vent kit
approved with furnaces listed in
this manual.
This concentric vent kit allows for
vertical or horizontal vent termina-
tion. The illustrations give a brief
view of the kit and its application.
See the section in this manual
under "Vent Flue and Combustion
Air Pipe Terminations" for more
information or consult the Installa-
tion and Operating Instructions
(IO-619B).
Vent
Combustion Air
( DCVK-20
Combustion Air
Roof Boot/Flashing
(Field Supplied)
Vent
(Vertical Installation)
Strap
(Field Supplied)
45 Elbow
(Field Supplied)
DCVK

(Horizontal Installation)

DCVK-30 )
Vent
Maintain 12" (18" for Canada)
minimum clearance above highest
anticipated snow level. Maximum of
24" above roof.
Support (Field Supplied)
DCVK
Combustion Air
Flush to
1" maximum
45 Elbow
(Field Supplied)
Combustion Air
Vent
25