Unit Location; Unit Installation; Mportant Ote To The Wner Regarding Roduct Arranty - Goodman GCVM970803BN User's Information Manual

Gas-fired warm air furnace
Table of Contents

Advertisement

Dear Homeowner, please recognize the following safety in-
formation. This information will alert you to the potential for
personal injury.
WARNING - Indicate hazards or unsafe practices which
COULD result in severe personal injury or death.
T
HIS PRODUCT CONTAINS OR PRODUCES A CHEMICAL OR
CHEMICALS WHICH MAY CAUSE SERIOUS ILLNESS OR
DEATH AND WHICH ARE KNOWN TO THE
C
ALIFORNIA TO CAUSE CANCER
.
REPRODUCTIVE HARM
T
O AVOID POSSIBLE EQUIPMENT DAMAGE
,
,
INJURY
FIRE OR DEATH
MUST BE OBSERVED REGARDING UNIT LOCATION
REQUIREMENTS AND OPERATING PROCEDURES
H
EATING UNIT SHOULD NOT BE UTILIZED WITHOUT
,
,
REASONABLE
ROUTINE
. I
SUPERVISION
F THE BUILDING IN WHICH ANY SUCH DEVICE
IS LOCATED WILL BE VACANT
THAT SUCH DEVICE IS ROUTINELY INSPECTED
.
AND MONITORED
IN THE EVENT THAT THE BUILDING MAYBE
EXPOSED TO FREEZING TEMPERATURES AND WILL BE
,
-
VACANT
ALL WATER
BEARING PIPES SHOULD BE DRAINED
THE BUILDING SHOULD BE PROPERLY WINTERIZED
THE WATER SOURCE CLOSED
BUILDING MAY BE EXPOSED TO FREEZING TEMPERATURES
,
AND WILL BE VACANT
ANY HYDRONIC COIL UNITS SHOULD
BE DRAINED AS WELL AND
HEAT SOURCES SHOULD BE UTILIZED
I
N
MPORTANT
OTE TO THE
L
W
IMITED
ARRANTY
Your limited warranty certificate is supplied as a separate
document with the unit installed by your contractor. Read
the limited warranty certificate carefully to determine what is
and is not covered and keep the warranty certificate in a
safe place. If you are unable to locate the warranty certifi-
cate please contact your installing contractor or contact cus-
tomer service (877-254-4729) to obtain a copy.
Before using this manual, check the serial plate for proper
model identification.
The installation and servicing of this equipment must be
performed by qualified, experienced technicians only.
U
L
NIT
OCATION
1. The furnace area and the vicinity of any other gas appli-
ances must be kept clear and free of combustible materi-
als, gasoline, and other flammable vapors and liquids.
Also, do not store or use flammable items such as paint,
varnish, or lacquer in the area.
WARNING
S
TATE OF
,
BIRTH DEFECTS OR OTHER
WARNING
,
PERSONAL
THE FOLLOWING INSTRUCTIONS
,
AIR
.
WARNING
,
INSPECTION
MAINTENANCE AND
,
CARE SHOULD BE TAKEN
,
MAINTAINED
,
.
IN THE EVENT THAT THE
,
,
IN SUCH CASE
ALTERNATIVE
.
O
P
WNER REGARDING
2. Do not store or use chlorine or fluorine products (bleaches,
cements, strippers, aerosols) near the unit. They can cor-
rode the heat exchanger.
3. Do not use the furnace closet as storage for brooms,
mops, brushes and oily rags or cloths. The area must be
kept clear, clean and free of lint. Furnace must be kept
free and clear of exposed or loose insulation materials in
the area of installation. Examine the furnace area when
the furnace or additional insulation is added since some
insulation materials may be combustible.
4. Make sure the furnace is always connected to an ap-
proved vent, in good condition, to carry combustion prod-
ucts outdoors.
5. Familiarize yourself with the controls that shut off the gas
and electrical power to the furnace. If the furnace is to be
shut down at the end of the heating season, turn off both
the gas and electrical power. For safety, always turn the
gas and electrical power off before performing service or
maintenance on the furnace.
6. Establish a regular maintenance schedule to insure effi-
cient and safe operation of the furnace. The furnace
should be checked at the beginning of each heating and
cooling season by a qualified service technician.
T
O AVOID PERSONAL INJURY OR FIRE
CLEARANCES TO COMBUSTIBLE SURFACES MUST BE
,
FOLLOWED
AND
7. Make certain the required clearances for the furnace are
always maintained. These clearances are listed on the
furnace clearance label. If any question develops, con-
tact the installer of the furnace or another qualified ser-
vicer.
U
I
NIT
NSTALLATION
RODUCT
Examine the furnace installation to determine the following:
1. All flue product carrying passages external to the furnace
(i.e. chimney, vent connector) are clear and free of ob-
structions.
2. The vent connector is in place, slopes upward and is
physically sound without holes or excessive corrosion.
3. The return air duct connection is physically sound, sealed
to the furnace casing, and terminates outside the space
containing the furnace.
4. The physical support of the furnace is sound without sag-
ging, cracks, or gaps around the base so as to provide a
seal between the support and the base.
5. There are no obvious signs of deterioration of the fur-
nace.
6. Check for proper burner flame performance. Flame should
extend directly outward from burners without curling, float-
ing, or lifting off.