PRODUCT DESIGN
( ADV8, AMV8, ACV9, AMV9, GMV8, GCV9, GMV9, GMV95 )
Thermostat Connection
Mode
24 Volts HOT
24 Volts COMMON
Low Stage Connection
For
"Two-Stage" Heating
High Stage Connection
For
"Two-Stage" Heating
Connection For
"Single-Stage" Cooling
Low Stage Connection
For
"Two-Stage" Cooling
High Stage Connection
For
"Two-Stage" Cooling
Continuous Fan
Connection
[Any Application]
24 V
T
W
OLT
HERMOSTAT
NOTE: Wire routing must not interfere with circulator blower
operation, filter removal, or routine maintenance.
As a two-stage furnace, the furnace integrated control
module provides terminals for both "W1" and "W2", and
"YLO" and "Y" thermostat connections. This allows the
furnace to support the following system applications: 'Two-
Stage Heating Only', 'Two-Stage Heating with Single-Stage
Cooling', and 'Two-Stage Heating with Two-Stage Cooling'.
Refer to the following figures and table for proper connec-
tions to the integrated control module.
64
Thermostat Wiring Reference Chart
Two-Stage Variable Speed Furnace
From Room
R
Thermostat
From Room
C
Thermostat
From Room
W1
Thermostat
From Room
W2
Thermostat
From Room
Y
Thermostat
From Room
Y1
Thermostat
From Room
Y2
Thermostat
From Room
G
Thermostat
IRING
Connection Options
On Two-Stage
To
R
Integrated
Control Module
On Two-Stage
To
C
Integrated
Control Module
On Two-Stage
To
W1
Integrated
Control Module
On Two-Stage
To
W2
Integrated
Control Module
On Two-Stage
To
Y
Integrated
Control Module
On Two Stage
To
Y-LO
Integrated Control
Module
On Two-Stage
To
Y
Integrated
Control Module
On Two-Stage
To
Integrated
G
Control Module
Low voltage connections can be made through either the
right or left side panel. Thermostat wiring entrance holes
are located in the blower compartment. The following figure
shows connections for a "heat only" system and "heat/cool
system".
This furnace is equipped with a 40 VA transformer to facili-
tate use with most cooling equipment. Consult the wiring
diagram, located on the blower compartment door, for fur-
ther details of 115 Volt and 24 Volt wiring.
Furnace Circulator Blower Operation
During Call From Thermostat
N/A
N/A
Circulator blower will operate on selected
Low Stage Heating speed tap
Circulator blower will operate on selected
High Stage Heating speed tap
Circulator blower will operate on selected
High Stage Cooling speed tap (5 second "ON"
delay and 45 second "OFF" delay)
Circulator blower will operate at 65% of
selected High Stage Cooling speed tap
Circulator blower will operate on selected
High Stage Cooling speed tap (5 second "ON"
delay and 45 second "OFF" delay)
Circulator blower will operate at
56% of selected
High Stage Cooling Speed Tap