Upper/Lower Diagnostics (Cont.) - Viking RDSOE306SS Service Manual

Single and double wall oven
Hide thumbs Also See for RDSOE306SS:
Table of Contents

Advertisement

Diagnostics

Upper/Lower Diagnostics (cont.)

Cycle Selector–To test the selector functions, the value is a four-digit value. The first digit is the cycle ID, from
0 to 9. The remaining three digits are the raw AD value, divided by two. Rotate "SET KNOB" and compare
values shown below.
Note: Start test with the selector in the OFF position.
From OFF, rotate the "SET KNOB" switch either direction
and compare display readout to charts shown here. Readings
should be within + – 10%.
Note: It takes several seconds for all 4 digits to come up
in the display. Turn the knob and then wait for 10 seconds to
let the display settle out.
Note: To test the UPPER selector, you must be in the UPPER
test mode. The same is true for the LOWER selector.
Setpoint
When SEtP is in display, press "MIN/SEC TIMER". With the thermostat in the OFF position, OF should be in the
display. Rotating the temperature dial to any temperature should register in the display. This will test the
potentiometer values of the thermostat.
AD–Raw setpoint AD (Analog to Digital) value.
SKIP THIS TEST
© 2012 Viking Preferred Service
Press
MIN/SEC
TIMER
Press
MIN/SEC
TIMER
Upper Oven
ID
1485
bake
2418
Convection Bake
3351
Tru Convection
4292
Convection Roast
5234
Convection Broil
6176
Hi broil
7126
Med broil
8073
Low Broil
9019
Self-Clean
Lower Oven
ID
1480
bake
2420
Convection Bake
3354
Tru Convection
4299
Convection Roast
5244
Convection Broil
6186
Hi broil
7132
Med broil
8072
Low Broil
9016
Self-Clean
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rddoe306ss

Table of Contents