Display Port (LVDS), X400
TFT displays with an LVDS port can be connected to this port. The connection of
18 bit displays up to a resolution of 1024x768 pixels is possible. The permissible
display clock rate is 20MHz to 66Mhz. The display is selected automatically in
accordance with the coding of the Select Inputs display. The display supply
voltages (3.3V and 5V) are connected via the graphic controller, dependent on the-
requirements of the connected displays. The maximum cable length is 50cm with a
transmission rate of 455MHz. Special cable properties are to be considered for the
pair of differential cables in accordance with the LVDS specification.
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
SIMATIC Box PC 620 Manual
C79000-G7076-C639-04
Signal
P5V_D_fused
+5V (fused) Display VCC
P5V_D_fused
+5V (fused) Display VCC
RXIN0–
LVDS Input signal Bit 0 (-)
RXIN0+
LVDS Input signal Bit 0 (+)
P3V3_D_fused
+3,3V (fused) Display VCC
P3V3_D_fused
+3,3V (fused) Display VCC
RXIN1–
LVDS Input signal Bit 1 (-)
RXIN1+
LVDS Input signal Bit 1 (+)
GND
GND
RXIN2-
LVDS Input signal Bit 2 (-)
RXIN2+
LVDS Input signal Bit 2 (+)
GND
GND
RXCLKIN-
LVDS clock pulse (-)
RXCLKIN+
LVDS clock pulse (+)
GND
GND
Reserved
Reserved