Displaying Power Policing On An Interface - Cisco Catalyst 4500 series Administration Manual

Hide thumbs Also See for Catalyst 4500 series:
Table of Contents

Advertisement

PoE Policing and Monitoring
Interface Admin
--------- ------ ---------- ---------- ---------- ------ -----
Gi2/1

Displaying Power Policing on an Interface

You can display power policing on an interface, on a module, or for all the PoE-capable line cards in a
chassis.
The following example shows output for the show power inline police command:
Switch# show power inline police
Available:623(w)
Interface Admin
--------- ------ ---------- ----------
Gi2/1
Gi2/2
Gi2/3
Gi2/4
Gi2/5
Gi2/6
The following table lists the interface and the status.
Interface Configuration
Gi2/1
Gi2/2
Gi2/3
Gi2/4
Gi2/5
Gi2/6
If you enter the show power inline command at the global level (show power inline police), the last
line of the output under the Oper Power field displays the total of true inline power consumption of all
devices connected to the switch.
Configuring Errdisable Recovery
By default, errdisable auto recovery for inline-power is disabled; when an interface is placed in an
errdisable state because of an inline-power policing violation, it remains in that state. You must enter
shut and then no shut on the affected interface to revive it.
Software Configuration Guide—Release IOS XE 3.6.0E and IOS 15.2(2)E
14-14
Oper
Admin
State
State
Police
auto
errdisable errdisable overdrawn
Used:6(w)
Remaining:617(w)
Oper
Admin
State
State
Police
auto
off
none
auto
on
none
auto
off
errdisable
auto
on
errdisable
auto
on
log
auto
on
errdisable
State
No PD connected, no policing configured.
PD connected, no policing configured.
No PD connected, policing configured (is enabled when PD is
connected). Policing action is errdisable.
PD connected, policing configured. Configured policing action is
errdisable. Port is currently operating within policing limits.
PD connected, policing configured. Configured policing action is log.
Port is currently operating within policing limits.
PD connected, policing configured. Configured policing action is
errdisable. Port is currently in errdisable state as it has overdrawn its
policed power level.
Chapter 14
Oper
Cutoff Oper
Police
Power
Power
0.0
0.0
Oper
Cutoff Oper
Police
Power
Power
----------
------ -----
n/a
n/a
0.0
n/a
n/a
16.7
n/a
0.0
0.0
ok
16.6
11.4
ok
16.6
11.2
overdrawn
0.0
0.0
Configuring Power over Ethernet
OL_28731-01

Advertisement

Table of Contents
loading