Pre-Issu (Original) Image = Bootflash:old_Image; Post-Issu (Targeted) Image = Bootflash:new_Image; Switch# Show Redundancy States My State = 13 -Active Peer State; Peer State = 8 -Standby Hot - Cisco Catalyst 4500 series Administration Manual

Hide thumbs Also See for Catalyst 4500 series:
Table of Contents

Advertisement

Chapter 7
Configuring the Cisco IOS XE In Service Software Upgrade Process
The new active supervisor engine is now running the new version of software, and the standby supervisor
Note
engine is running the old version of software and is in the standby hot state.
Switch# show redundancy states
Redundancy Mode (Operational) = Stateful Switchover
Redundancy Mode (Configured) = Stateful Switchover
Communications = Up
client_notification_TMR = 240000 milliseconds
Once Runversion has completed, the new active supervisor engine will be running the new version of
software and the previously active supervisor engine will now become the standby supervisor engine.
The standby will be reset and reloaded, but it will remain on the previous version of software and come
back online in standbyhot status. The following example shows how to verify these conditions:
Switch# show redundancy
Redundant System Information :
------------------------------
Switchovers system experienced = 0
Configured Redundancy Mode = Stateful Switchover
Current Processor Information :
------------------------------
OL-30933-01

Pre-ISSU (Original) Image = bootflash:old_image

Post-ISSU (Targeted) Image = bootflash:new_image

RP State = Standby
ISSU State = Run Version
Operating Mode = Stateful Switchover
Current Image = bootflash:old_image
Pre-ISSU (Original) Image = bootflash:old_image
Post-ISSU (Targeted) Image = bootflash:new_image
my state = 13 -ACTIVE
peer state =
8 -STANDBY HOT
Mode = Duplex
Unit = Primary
Unit ID = 6
Redundancy State = Stateful Switchover
Manual Swact = enabled
client count = 64
keep_alive TMR = 9000 milliseconds
keep_alive count = 0
keep_alive threshold = 18
RF debug mask = 0
Available system uptime = 12 minutes
Standby failures = 0
Last switchover reason = none
Hardware Mode = Duplex
Operating Redundancy Mode = Stateful Switchover
Maintenance Mode = Disabled
Communications = Up
Active Location = slot 6
Current Software state = ACTIVE
Uptime in current state = 9 minutes
Slot = 5