Genie ZX-135/70 Service And Repair Manual page 191

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

October 2016
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
523612
12
637
Internal ECU monitoring
detection reported error
523612
12
1170 Internal software error ECU
523612
14
973
Softwarereset CPU SWReset_0
523612
14
974
Softwarereset CPU SWReset_1
523612
14
975
Softwarereset CPU SWReset_2
523613
0
856
Maximum positive deviation of
rail pressure exceeded
(RailMeUn0)
523613
0
857
Maximum positive deviation of
rail pressure in metering unit
exceeded (RailMeUn1)
523613
0
858
Railsystem leakage detected
(RailMeUn10)
523613
0
859
Maximum negative deviation of
rail pressure in metering unit
exceeded (RailMeUn2)
523613
0
860
Negative deviation of rail
pressure second stage
(RailMeUn22)
523613
0
862
Maximum rail pressure exceeded
(RailMeUn4)
523613
1
861
Minimum rail pressure exceeded
(RailMeUn3)
523613
2
864
Setpoint of metering unit in
overrun mode not plausible
523615
3
594
Metering unit (Fuel-System);
short circuit to battery highside
Part No. 1268558
Deutz TD 2.9 L4 Engine Fault Codes
SPN
523615
523615
523615
523615
523615
523619
523698
523717
523718
523718
523718
523718
523766
523767
ZX-135/70
Service and Repair Manual
FMI KWP Description
3
596
Metering unit (Fuel-System);
short circuit to battery low side
4
595
Metering unit (Fuel-System);
short circuit to ground high side
4
597
Metering Unit (Fuel-System);
short circuit to ground low side
5
592
Metering unit (Fuel-System);
open load
12
593
Metering unit (Fuel-System);
powerstage over temperature
2
488
Physical range check high for
exhaust gas temperature
upstrem (SCR-CAT)
11
122
Shut off request from supervisory
monitoring function
12
125
Timeout Error of
CAN-Transmit-Frame AmbCon;
Weather environments
3
1488 SCR mainrelay; short circuit to
battery (only CV56B)
4
1489 SCR mainrelay; short circuit to
ground (only CV56B)
5
1486 SCR mainrelay; open load (only
CV56B)
12
1487 SCR mainrelay; powerstage over
temperature (only CV56B)
9
281
Timeout Error of
CAN-Receive-Frame Active
TSC1AE
9
282
Timeout Error of
CAN-Receive-Frame Passive
TSC1AE
179