Panasonic KX-TCD705RUM Service Manual page 55

Table of Contents

Advertisement

14.3.6. PSTN Line
Address
Default
0F00
03
0F01
0D
0F02
10
0F03
03
0F04
0F
0F05
15
0F06
28
0F07
3C
0F08
64
0F09
0A
0F0A
4A
0F0B
08
0F0C
14
0F0D
46
0F0E
28
0F0F
82
0F10
82
0F11
FF
Name
UserCfg-1.Mode
UserCfg-2.Mode
UserCfg.RPauseTime
UserCfg.DialPauseTime
Cfg-1
Cfg-2
MakeTime
BreakTime
DtmfTime
InterDigitDtmfTime
InterDigitPulseTime
CalibBreakTime[0]
CalibBreakTime[1]
CalibBreakTime[2]
CalibBreakTime[3]
CalibBreakTime[4]
CalibBreakTime[5]
LineSeizureEndTime
Type
D
User configuration (MMI) - mode settings 1.
Bit
0 : "R" mode, 0=earth break, 1=loop break
2..1: Dial mode, 00:pulse, 01:DTMF
3..7: Reserved
D
User configuration (MMI) - mode settings 2.
Bit
0..1: short "R" key time selection
00= short, 01=long, 10=extra-long
2..3: long "R" key time selection
00= short, 01=long, 10=extra-long,
11=undef (uses same time as specified for short R key)
4..7: Reserved
Defaults to 0000 1101
D
User configuration (MMI) - "R"-pause. If disabled, normal
dial pause (DialPauseTime) is used.
Bit 7..0 : "R" pause time, zero value allowed
Unit : 50 ms, defaults to 800 ms.
D
User configuration (MMI) - dial pause.
Bit 3-0 : dial pause in 1 sec units , zero not allowed.
Bit 7-4 : unused
Defaults to 3 seconds
D
PSTN line configuration 1 (factory settings)
Bit
0: EarthBreakEnable , Earth break 1=enable 0=disable
1:LoopBreakEnable, Loop break 1=enable,0=disable
2:PulseDialEnable, Pulse dial 1=enable 0=disable
3:RPauseEnable, usage of "R" pause 1=enable, 0=disable
4:PulseType,0=normal puls-type
1=('0'=1 pils,..'9'=10 puls's).
5: InterDigitLowImp. controls interdigit impedance.
1: keep low-impedance during interdigit pause
0: normal impedance during interdigit pause
6: LowImpLineSeizure. Special low-imp line seizure
(Australian) , 1=enable , 0=disable
7: TwoLines. line config 0=one line, 1=two lines Defaults to
0000 0111B.
PSTN line configuration 2 (factory settings)
Bit
0: Meter-pulse, 1=enable, 0=disable
1: DialToneMode, dial tone detection 1=enable 0=disable
2: BusyToneMode. busy tone detection 1=enable 0=disable
3: CurrentLimiterMode, 1=enable, 0=disable
4: RingToneMode. Ring tone detection 1=enable 0=disable
5: HookRelayEnable, 1=enable, 0=disable (if same port is
used
for
earth-control
HookRelayEnable cannot both be set to 1).
6..7: not used
Defaults to 0001 0101B.
D
Pulse make time.
Unit : 1 ms. defaults to 40 ms.
D
Pulse break time
Unit : 1 ms, defaults to 60 ms.
D
DTMF tone pulse time.
Unit : 1 ms, defaults to 100 ms.
D
Inter-digit time in DTMF mode.
Unit : 10 ms , defaults to 100ms.
D
Inter-digit time in Pulse mode.
Unit : 10 ms, defaults to 740 ms.
D
Calibrated loop-break time for short break
Unit : 10 ms, defaults to 80 ms.
D
Calibrated loop-break time for long break
Unit : 10 ms, defaults to 200 ms.
D
Calibrated loop-break time for extra-long break
Unit : 10 ms, defaults to 700 ms.
D
Calibrated earth-break time for short break
Unit : 10 ms, defaults to 400 ms.
D
Calibrated earth-break time for long break
Unit : 10 ms, defaults to 1300 ms.
D
Calibrated earth-break time for extra-long break
Unit : 10 ms, defaults to 1300 ms.
D
Line seizure end-time - time after hook-on. Meter-pulse
detection continues during this period of time. 00h or FFh
means 10 ms.
Unit : 10 ms, defaults to 10 ms.
55
KX-TCD705RUM / KX-TCD705RUS
Description
EarthBreakEnable
and

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tcd705rus

Table of Contents