BIT SWITCHES
IP Fax Switch 07 [SP No. 1-111-008]
No.
FUNCTION
TSI information
0
0: Not added, 1: Added
DCN transmission setting at T1
1
timeout
0: Not transmitted, 1: Transmitted
2
Not used
Hang up setting at DIS reception
disabled
3
0: No hang up
1: Hang up after transmitting DCN
Number of times for training
4
0: 1 time, 1: 2 times
Space CSI transmission setting at
5
no CSI registration
0: Not transmitted, 1: Transmitted
6-7
Not used
IP Fax Switch 08 [SP No. 1-111-009]
No.
FUNCTION
T1 timer adjustment
Adjusts the T1 timer.
The default is "00" (35 seconds).
0-1
Bit 1: 0, Bit 0: 0 = 35 sec
Bit 1: 0, Bit 0: 1 = 40 sec
Bit 1: 1, Bit 0: 0 = 50 sec
Bit 1: 1, Bit 0: 1 = 60 sec
T4 timer adjustment
Adjust the T4 timer.
The default is "00" (3 seconds).
2-3
Bit 3: 0, Bit 2: 0 = 3 sec
Bit 3: 0, Bit 2: 1 = 3.5 sec
Bit 3: 1, Bit 2: 0 = 4 sec
Bit 3: 1, Bit 2: 1 = 5 sec
T0 timer adjustment
Bit 5: 0, Bit 4: 0 = 75 sec
4-5
Bit 5: 0, Bit 4: 1 = 120 sec
Bit 5: 1, Bit 4: 0 = 180 sec
Bit 5: 1, Bit 4: 1 = 240 sec
6-7
Not used
B819/B820
CÓPIA NÃO CONTROLADA
Adds or does not add TSI information to
NSS(S).
Transmits or does not transmit DCN at T1
timeout.
Do not change this setting.
Sets whether the machine disconnects after
DIS reception.
Selects the number of times training is done
at the same bit rate.
When "0" is selected, frame data is enabled.
When "1" is selected, the transmitted data is
all spaces.
Do not change these settings.
-
-
Adjusts the fail safe timer. This timer sets the
interval between "setup" data transmission
and T.38 phase decision. If your destination
return is late on the network or G3 fax return
is late, adjust the longer interval timer.
The default is "00" (75 seconds).
Do not change these settings.
106
CÓPIA NÃO CONTROLADA
COMMENTS
COMMENTS
SM