Ultrasonic Volumetric Protection; Sensor Adjustment; System Reset - Gemini 932 Series Installation And Use Manual

Hide thumbs Also See for 932 Series:
Table of Contents

Advertisement

I
nsert the WHITE connector in the "W" marked socket and the RED connector in the "R" marked
socket (see figure below).
Install the ultrasonic sensors on the top part of the windshield internal pillars, away from the air vents
and point them towards the center of the rear window
T
o check the sensitivity level proceed as follows
!
With the alarm system disarmed, roll down the front window approx. 20 cm.
!
Adjust the trimmer at a medium setting.
!
Close all doors, bonnet and boot and arm the system.
!
During the arming delay introduce an object in the cabin through the window and move it around;
the status LED will turn off to signal a presence.
!
If the sensitity lelvel is too high or too low, readjust the trimmer and repeat the above procedure
SENSITIVITY
ADJUSTMENT
!
This procedure must therefore only be used in case of need, before programming the
To reset the system proceed as follows:
!
Disconnect the alarm p
!
S
hort-circuit the RED and BLACK wires of the 2-pin
!
Connect the alarm; 4 acoustic signals and 4 flashes of the turn indicators will confirm the alarm is
powered
.
!
Remove the previously created short-circuit; the status LED lights up steady.
!
Turn ignition key "ON";
approx. 3 seconds
!
Turn ignition key "OFF";
PAGE 16 - INSTALLER MANUAL
15.0 -

ULTRASONIC VOLUMETRIC PROTECTION

15.1 - CO
NNECTION AND POSITIONING

15.2 - SENSOR ADJUSTMENT

16.0 - SYSTEM RESET

By activating the following procedure, the system returns to the
system or learning the turn indicator flashes.
ower supply
.
reset is confirmed by an aucoustic signal and the wailing of the siren for
.
the LED will turn OFF. There are no acoustic signals
.
:
factory default setting.
LED
connector
ULTRASONIC
CELLS
CONNECTIONS
.
.
.

Hide quick links: