Have the system notify you if your children do not arrive at home by a
predetermined time.

Home security

The Simon XT allows you to control which sensors are active at any given time.
Table 4 below describes the arming levels that you can set from the control
panel.
Table 4: Arming levels
Leve
Function
l
0
Subdisarm
1
Disarm
2
Arm door and window
sensors (exterior)
3
Arm motion sensors
(interior)
4
Arm doors/windows and
motion sensors
Arming/disarming
Arming a sensor makes it active and allows the panel to generate an alarm when
a door or window is opened or when an unauthorized person enters a specific
area. Disarming makes the sensor inactive in the system. The current arming
level is shown on the panel display and changes in arming level are announced
on the speaker.
To subdisarm (level 0):
1. Enter the master code while the system is disarmed.
The panel displays and speaks Subdisarmed, the Disarm button blinks, and
the panel beeps once.
2. When you finish accessing the temporarily unprotected areas, press Disarm
to return to the disarmed level.
To disarm (level 1):
1. Press Disarm.
Simon XT User Manual
Description
If your system includes 24-hour protection sensors, you
must subdisarm the panel before accessing these areas to
avoid causing an alarm. Environmental sensors (such as
smoke or carbon monoxide detectors) stay active at all
times.
In this level, only 24-hour sensors are active. Environmental
sensors (such as smoke or carbon monoxide detectors)
stay active at all times.
This level arms the door and window sensors, while leaving
the interior motion sensors disarmed.
This level arms the interior motion sensors, while leaving
the exterior door and window sensors disarmed.
This level arms all sensors.