CARE OF THE UNIT
1.
Only plug the unit into the correct
220-240V~ 50Hz AC 10
2.
Hold the plug when unplugging the unit, never pull on the cord.
3.
Do not place the unit in direct sunlight. This can fade the plastic case.
4.
Do not operate the unit in a confined space.
5.
Do not place objects on top of the unit. This blocks the air outlet.
6.
Do not place the unit where the air inlets or outlets may be blocked by curtains or
furniture.
7.
Keep the filters clean.

OVERHEAT PROTECTION

This unit is fitted with an overheat prevention device. If the unit overheats it will automatically
turn off. The unit can be restarted after 30 minutes.

ERROR CODES

Error codes are shown on the display should a fault occur.
E1: Indicates open circuit or short circuit in temperature sensor and PCB.
E2: Indicates open circuit or short circuit in temperature sensor, copper tube and PCB.
E4: Indicates the internal water container is full. Refer to WATER DRAIN.
AMP power supply.
12
TROUBLE SHOOTING
Never try to repair or dismantle the air conditioner yourself. Unauthorized repairs may
result in the loss of warranty and can endanger the user and their property.
Problem
Cause
The air conditioner
No power supply.
does not operate.
Error code E4 or water drain
warning indictor is displayed,
indicating the internal water
container is full.
The start timer function is
active.
The air conditioner
The air conditioner is in direct
does not seem to
sunlight.
operate efficiently.
Windows or doors are open.
The filters are dirty.
The air inlets or outlets are
blocked.
The room temperature is
below the set temperature.
The air conditioner
The air conditioner is not
is noisy.
level.
The compressor
The overheat protection is
does not work.
activated.
The remote control
The distance between the
does not function.
remote control and the air
conditioner is too great.
The batteries are flat.
If you have any issues with your unit, please contact Glen Dimplex for
your nearest service agent. Proof of purchase is required at the time of
service.
Solution
Connect to a functioning power
supply socket and switch on.
Empty the internal water
container.
(Refer to WATER DRAIN)
Press the POWER button to
deactivate the TIMER function.
Close the curtains.
Close windows and doors.
Clean the filters.
Remove the blockage.
Lower set temperature.
Place the air conditioner on an
even, solid surface.
Wait 30 minutes until the
temperature has decreased,
then turn the air conditioner on
again.
Note: Compressor operation
begins 3 minutes after the unit
is switched on.
Move closer to the air
conditioner. Aim the remote
control directly at the control
panel.
Replace the batteries.