11. Options and peripheral devices
No.
Product name
6)
Connector set
MR-CCN1
Junction terminal
7)
block
(recommended)
8)
STO cable
MR-D05UDL3M-B
9)
Short-circuit
connector

11.1.2 MR-D05UDL3M-B STO cable

This cable is for connecting an external device to the CN8 connector.
(1) Configuration diagram
(2) Internal wiring diagram
Model
Junction terminal block PS7DW-20V14B-F is not option. For using the
junction terminal block, option MR-J2HBUS_M is necessary. Refer to
section 11.6 for details.
Cable model
MR-D05UDL3M-B
MR-D05UDL3M-B
(Note)
Yellow (with black dots)
Yellow (with red dots)
Gray (with black dots)
Gray (with red dots)
White (with black dots)
White (with red dots)
Note. Do not use the two core wires with orange insulator (with red or black dots).
Description
Connector: 10120-3000PE
Shell kit: 10320-52F0-008
(3M or equivalent)
PS7DW-20V14B-F
(Yoshida Electric Industry)
MR-J2HBUS_M
Connector set: 2069250-1
(TE Connectivity)
Cable length
3 m
Connection cable for the CN8 connector
Servo amplifier
1
2
3
STOCOM
4
STO1
5
STO2
6
TOFB1
7
TOFB2
8
TOFCOM
Plate
Shield
11 - 5
Application
Connection
cable for
the CN8
connector
Supplied
with servo
amplifier
Application
CN8
CN8 connector
2
4
6
8
1
3
5
7
Viewed from the connection part