Refrigerant Address - Mitsubishi Electric PUHZ-P200YKA.UK Service Manual

Table of Contents

Advertisement

The operation data will appear.
The Compressor-Accumulated operating (COMP. run) time is 10-hour unit,
and the Compressor-Number of operation times (COMP. ON/OFF) is a 100-
time unit (fractions discarded).
Navigating through the screens
• To go back to the Main menu ..........
• To return to the previous screen .......

Refrigerant address

Single refrigerant system
In the case of single refrigerant system, the refrigerant address
is "00" and no operation is required.
Simultaneous twin, triple units belong to this category
(single refrigerant system).
[1:1]
Refrigerant
address=00
Outdoor
unit
Indoor unit
01
Remote
controller
OCH582B
button
button
[Twin]
Refrigerant
address=00
Outdoor
unit
Indoor unit
Indoor unit
01
02
Remote
controller
Multi refrigerant system (group control)
Up to 16 refrigerant systems (16 outdoor units) can be con-
nected as a group by 1 remote controller. To check or set the
refrigerant addresses.
Refrigerant
Refrigerant
address
address
00
01
Outdoor
Outdoor
unit
unit
Indoor unit
Indoor unit
01
01
Remote
controller
93
3
Smooth maintenance
Ref. address
Cool
COMP. current
COMP. run time
COMP. On / Off
COMP. frequency
Return:
Page
Smooth maintenance
Cool
Ref.address
Sub cool
OU TH4 temp.
OU TH6 temp.
OU TH7 temp.
Return:
Page
Smooth maintenance
Ref.address
Cool
IU air temp.
IU HEX temp.
IU filter time
Return:
Page
Refrigerant
Refrigerant
address
address
02
15
Outdoor
Outdoor
unit
unit
Indoor unit
Indoor unit
01
01
A
Hr
times
Hz
Hr

Hide quick links: