(2) Functions available when setting the unit number to 01–03 or AL (07 in case of wireless remote controller)
• When setting functions for an indoor unit in an independent system, set the unit number to 01 referring to 4 setting the
indoor unit number of Operating Procedure.
• When setting functions for a simultaneous- Twin Triple indoor unit system, set the unit number to 01 to 03 for each indoor
unit in case of selecting different functions for each unit referring to 4 setting the indoor unit number of Operating Procedure.
• When setting the same functions for an entire simultaneous Twin Triple-indoor unit system, set refrigerant address to AL (07
in case of wireless remote controller) referring to 4 setting the indoor unit number of Operating Procedure.
Function
Filter sign
100h
2500h
No filter sign indicator
Quiet
Air flow
Standard
( Fan speed )
High ceiling
No.of air outlets
4 directions
3 directions
2 directions
Optional high efficiency Not supported
Supported
filter
No vanes ( Vane No.3 setting : PLA only )
Vane setting
Vane No.1 setting
Vane No.2 setting
Not supported
Optional humidifier
( PLA only )
Supported
Vane differential setting No.1 setting ( TH5: 24–28°C )
No.2 setting ( Standard , TH5:28–32°C ) 14
in heating mode
( cold wind prevention )
No.3 setting ( TH5: 32–38°C )
Swing
Not available Swing
Available
Set temperature in heating Available
mode ( 4 deg up ) *
Not available
Fan speed during the
Extra low
Stop
heating thermo OFF
Set fan speed
Set fan speed
Fan speed during the
Stop
cooling thermo OFF
Detection of abnormality of Available
the pipe temperature ( P8 ) Not available
* PKA-HAL/KAL: 2 deg up
PEAD-RP
JA(L)Q
Function
Filter sign
100h
2500h
No filter sign indicator
External static pressure 35/50/70/100/150Pa
External static pressure 35/50/70/100/150Pa
Available
Set temperature in heating
mode ( 4 deg up )
Not available
Fan speed during the
Extra low
heating thermo OFF
Stop
Set fan speed
Fan speed during the
Set fan speed
cooling thermo OFF
Stop
Available
Detection of abnormality
of the pipe
Not available
Mode No.11
Setting No.
Settings
Vane No.3 setting
1
No Vanes
2
Vane No.1 setting
3
Vane No.2 setting
* Be careful of the smudge on ceiling.
OCH582B
Mode
Settings
No.
07
08
09
10
11
13
}
PLA-BA
23
Wave air flow
24
25
27
28
Setting
Mode
Settings
No.
No.
1
07
2
3
Refer to the right table
08
Refer to the right table
10
1
24
2
1
25
2
3
1
27
2
1
28
2
PLA-BA
Less smudging
( Downward position than the standard )
Standard
Less draft * (Upward position than the standard) Less draft * (Upward position than the standard)
: Initial setting ( Factory setting )
- : Not available
Ceiling
4-Way
Setting
suspended
cassette
No.
PLA-BA
PCA-KAQ
PKA-HAL PKA-KAL
1
2
3
1
2
3
1
2
3
1
2
1
2
3
1
2
1
2
3
1
2
1
2
1
2
3
1
2
1
2
: Initial setting
External static
( Factory setting )
pressure
35Pa
50Pa
70Pa
100Pa
150Pa
No vane function
Standard
76
Floor
Wall mounted
concealed
standing
PSA-KA
PSA-KA
Setting No.
Initial setting
( Factory setting )
Mode No. 08 Mode No. 10
1
2
1
3
1
2
2
2
2
3
PCA-KAQ
Ceiling
PEA-GA