barbas Cuatro-2 60 Installation Instructions Manual page 19

Table of Contents

Advertisement

CUATRO-2 60
CUATRO-2 70
° Now connect the fl exible hoses to the 2 collar adaptors (Ø125 mm) on
the top of the fi re and to the metal fi tting box on the air exit grids that are
being used (do not forget to fi t hose clamps).
° Ensure that the fl exible hose connections are gastight.
° The air exit grids cannot be fi tted until a few days later, once the
masonry has been pointed and allowed to dry. If one or more channels
are connected leading to other rooms, these rooms must be fi tted with
closable grids. These are available from your dealer, as well as the
fl exible hoses and clamps required.
° Within a range of 30 cm either side and 50 cm above the escape opening
(exit grids), there must be no fl ammable materials (e.g. wooden ceiling,
fi tted furniture).
CUATRO-2 80
19