CAUTION: UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit component damage. Operation of unit on improper line voltage constitutes
abuse and may cause unit damage that could affect warranty.
B. ROUTING POWER LEADS INTO UNIT
Use only copper wire between disconnect and unit. The high-voltage leads should be in a conduit until they enter the unit; conduit termination
at the unit must be watertight. Run the high-voltage leads through the hole on the control box side of the unit (see Fig. 7 for location). When the
leads are inside the unit, run leads to the control box (Fig. 8). For single-phase units, connect leads to the black and yellow wires (see Fig. 9).
C. CONNECTING GROUND LEAD TO UNIT GROUND
Refer to Fig. 8 and 9. Connect the ground lead to the chassis using the unit ground in the control box.
D. ROUTING CONTROL POWER WIRES
Form a drip-loop with the thermostat leads before routing them into the unit. Route the thermostat leads through grommeted hole provided in unit
into unit control box (See Fig. 7). Connect thermostat leads and unit power leads as shown in Fig. 9, 10A & 10B.
Route thermostat wires through grommet providing a drip-loop at the panel. Connect low-voltage leads to the thermostat as shown in Fig. 10A
& 10B.
TOP COVER
Power Wiring
Control Wiring
Condenser Airflow
*Separate disconnect per NEC
(National Electrical Code) required
for electric heater when single-
Evaporator Airflow
point conection is not used.
Fig. 4—Typical installation
1" (25mm) MIN.
Fig. 5—Condensate Trap (Using Tubing)
1" min.
Fig. 6—PVC Condensate Trap
Table 3—Minimum Airflow for Safe Electric Heater Operation (CFM)
030
750
INDOOR
THERMOSTAT
RETURN
AIR
FROM
POWER
SOURCE
POWER AND
LOW-VOLTAGE
ENTRY
COMPOSITE
RUST-PROOF
BASEPAN
CONDENSATE
DRAIN
CONNECTION
TRAP
OUTLET
2" (50mm) MIN.
TRAP
OUTLET
036
042
900
1050
—7—
DISCONNECT
PER NEC*
(UNIT AND
ELECTRIC
HEATER)
C00008
2" min.
048
1200
C00008
C99013
C00009
060
1500

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents