Heating; Continuous Fan; Defrost; Electric Resistance Heating - Payne PA3Z Installation Manual

Single packaged air conditioner
Table of Contents

Advertisement

PA3Z
SPEED TAP
WATTS/C.F.M
1
024
2
2
030
3
1
036
2
3
042
4
1
2
048
3
4
1
2
060
3
4
Air delivery values are based on operating voltage of 230-v., dry coil, without filter or electric heater. Deduct wet coil, filter, and electric heater pressure drops to obtain
external static pressure availabe for ducting.
Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of rated cooling capacity. Evaporator coil frosting may occur at airflows below this
point.
Dashes indicate portions of the table that are beyond the blower motor capacity or are not recommended.
C. COOLING OPERATION (SIZES 048 AND 060)
These units utilize a 2 stage indoor thermostat. With a first stage call for cooling (Y1), the indoor fan (low stage) energizes immediately whereas
the contactor energizes after a 5 minute time delay (in case of an initial start-up) starting the compressor (low stage) and the outdoor fan motor.
If the low stage operation cannot satisfy the cooling demand, the second stage cooling (Y2) energizes switching the compressor into high stage
cooling through energizing an internal solenoid valve inside the scroll compressor and switching the indoor fan into high stage. When second stage
cooling is satisfied, Y2 de-energizes switching the compressor and the indoor fan into low stage cooling. When the low stage cooling demand is
met, Y1 de-energizes shutting the compressor, indoor fan and the outdoor fan.
D. HEATING OPERATION (SIZES 024-042)
With a call for heating (W2), the auziliary or electric heat energizes along with the indoor blower. In case of staged heating, W3 is energized if
the demand is not met. The highest airflow selected is run while the electric heat is in operation. When heating demand is met, W3 and W2
sequentially de-energize shutting the indoor fan and the electric heater.
E. HEATING OPERATION (SIZES 048 AND 060)
With a call for heating (W2), the auxiliary electric heater is energized along with the indoor blower. If the demand is not met, W3 is energized
in case of staged heating. When heating demand is satisfied, W3 and W2 sequentially de-energize along with the indoor fan blower.
F. CONTINUOUS FAN
With the continuous Indoor fan option selected on the thermostat, G is continuously energized. In case of 024-042 units, the selected airflow setting
is provided. In case of 048 and 060 units, the system runs low stage (Y1) airflow for continuous fan operation.
G. DEFROST
Defrost board (DB) is a time and temperature control, which includes a field-selectable time period between checks for defrost (30, 60, 90 and
120 minutes). The time period is factory-set at 60 minutes and should only be adjusted by a trained service person. Electronic timer and defrost
cycle start only when contactor is energized and defrost thermostat (DFT) is closed.
Defrost mode is identical to Cooling mode. The outdoor fan motor stops because of "OF1" and "OF2" contacts opening on the defrost board, a
bank of optional electric heat turns on to warm air supplying the conditioned space.
Table 7—Dry Coil Air Delivery* Horizontal Discharge
(Deduct 10 percent for 208 Volt Operation)
0.1
0.2
Watts
-
99
C.F.M.
-
848
Watts
-
-
C.F.M
-
-
Watts
-
155
C.F.M
-
1108
Watts
-
-
C.F.M.
-
-
Watts
180
166
C.F.M.
1344
1215
Watts
-
-
C.F.M.
-
-
Watts
269
283
C.F.M.
1440
1404
Watts
-
-
C.F.M.
-
-
Watts
204
C.F.M.
1129
Watts
C.F.M.
Watts
386
398
C.F.M.
1680
1652
Watts
440
C.F.M.
1745
Watts
224
235
C.F.M.
1334
1288
Watts
-
-
C.F.M.
-
-
Watts
608
626
C.F.M.
1931
1900
Watts
737
755
C.F.M.
2093
2061
EXTERNAL STATIC PRESSURE
.03
0.4
0.5
100
118
130
142
793
757
698
632
-
-
-
222
-
-
-
970
146
157
170
995
951
884
-
-
-
261
-
-
-
1117
179
191
204
216
1172
1136
1095
1051
-
261
276
290
-
1343
1304
1272
305
321
336
349
1369
1333
1301
1273
418
432
450
465
1572
1543
1504
1475
209
216
229
236
1087
1027
994
932
233
245
254
266
1164
1122
1066
1025
409
418
425
435
1625
1583
1555
1515
448
457
462
469
1717
1684
1651
1612
251
266
277
291
1259
1224
1181
1157
286
301
311
325
1333
1296
1261
1232
643
660
668
685
1878
1844
1817
1789
770
787
799
817
2028
2001
1971
1934
—16—
0.6
0.7
0.8
0.9
-
-
-
-
-
-
233
244
257
918
861
795
-
-
-
-
-
-
-
-
275
286
291
1053
1014
980
-
-
-
-
-
-
301
316
329
1234
1190
1148
360
-
-
1239
-
-
480
490
503
1441
1418
1380
249
881
276
289
954
906
438
441
451
1477
1444
1403
477
480
485
1573
1537
1508
298
-
-
1117
-
-
333
344
370
1199
1170
1062
697
-
-
1755
-
-
826
812
782
1899
1850
1757
1.0
-
-
260
729
-
-
315
877
-
-
342
1100
-
-
518
1332
486
1470
-
-
-
-
-
-
-
-