Press key 1 or 2 to set the required power level during the fi rst operating cycle.
Confi rm the power setting by pressing the SET key.
Press key 1 or 2 to set the required room temperature during the fi rst operating cycle.
Confi rm the temperature by pressing the SET key.
Programming automatically passes to the second operating cycle. To continue programming
for the second cycle, proceed in sequence with the steps given for the fi rst cycle. The number
2 appears on the display, indicating the second operating cycle. If you do not want to program
a second cycle, set START and STOP of the second programming cycle to OFF.
6.6 PARAMETERS MENU
The User can only interact with the TIME METER STORAGE in the parameter menu, as described in the table below: the other parameters can only be used
by an authorised service centre.
Press key 6 for a few seconds. Use key 5 or 6 to scroll the menu that appears on the right
display until the scrolling readout MENU PARAMETERS appears.
Confi rm by pressing the SET key.
Use key 5 or 6 to scroll the menu that appears on the right display until the scrolling readout
MEMORY COUNTERS appears.
Confi rm by pressing the SET key.
The scrolling readout HOURS TOTAL appears on the right display and the total hours of
operation on the left display.
Use key 5 to go back within the time meter storage menu.
Press key 6.
The scrolling readout HOURS PARTIAL appears on the right display and the number of
partial hours on the left display.
Use key 5 to go back within the time meter storage menu.
Press key 6.
The scrolling readout NUMBER START appears on the right display and the number of
actual starts on the left display.
Use key 5 to go back within the time meter storage menu.
Press key 6.
The last 5 alarms (e.g.: ALL) appear on the right display and the readout MEM1, MEM2,
MEM3, MEM4, MEM5 on the left display.
Use key 5 to go back within the time meter storage menu.
Press the SET key to return to the initial display.
26
Description of activity
TIME METER STORAGE
Description of activity
H07023380 / DT2000477-03
Display
SET EN PO 1 (scrolling readout)
SET TEMP ROOM 1 (scrolling readout)
START EN PROGRAM 2 (scrolling readout)
DT2011679-00
Display
MENU PARAMETERS
MEMORY COUNTERS
HOURS TOTAL
HOURS PARTIAL
NUMBER START
ALL (scrolling readout)
DT2011676-00