TABLE 50: SUPERHEAT CHARGING
SUCTION PRESSURE
PSIG (Service Port)
61.5
64.2
67.1
70
73
76
79.2
82.4
84.1
92.6
*.
From TMP chart.
TABLE 51: COOLING SUPERHEAT 6-1/2 TON HEAT PUMP
OUTDOOR
TEMP °F
55
65
34.5
70
32.5
75
30.4
80
28.4
85
26.3
90
22.0
95
17.7
100
13.9
105
10.0
110
6.2
115
-
46
*
2
4
6
8
0
35
37
39
41
43
37
39
41
43
45
39
41
43
45
47
41
43
45
47
49
43
45
47
49
51
45
47
49
51
53
47
49
51
53
55
49
51
53
55
57
50
52
54
56
58
55
57
59
71
73
57
59
61
34.8
35.1
35.4
32.9
33.3
33.7
31.0
31.5
32.0
29.0
29.7
30.3
27.1
27.9
28.6
23.0
23.9
24.9
18.9
20.0
21.2
14.9
15.9
17.0
10.9
11.8
12.8
7.0
7.8
8.6
-
-
-
SUCTION TUBE TEMPERATURE
10
12
14
16
18
45
47
49
51
53
47
49
51
53
55
49
51
53
55
57
51
53
55
57
59
53
55
57
59
61
55
57
59
61
63
57
59
61
63
65
59
61
63
65
67
60
62
64
66
68
65
67
69
71
73
SUCTION SUPERHEAT °F
INDOOR WB TEMP °F
63
65
67
35.6
35.9
36.2
34.1
34.5
34.9
32.5
33.0
33.6
30.9
31.6
32.2
29.4
30.1
30.9
25.8
26.8
27.8
22.3
23.5
24.6
18.0
19.0
20.1
13.7
14.6
15.5
9.4
10.2
11.0
5.0
5.7
6.4
127421-YIM-C-0606
20
22
24
26
28
55
57
59
61
63
57
59
61
63
65
59
61
63
65
67
61
63
65
67
69
63
63
67
69
71
65
67
69
71
73
67
69
71
73
75
69
71
73
75
77
70
72
74
76
78
75
77
79
81
83
69
71
37.0
37.7
35.8
36.7
34.6
35.6
33.4
34.5
32.2
33.5
29.5
31.2
26.8
29.0
22.5
24.9
18.2
20.8
13.8
16.7
9.5
12.6
Unitary Products Group
30
32
34
65
67
69
67
69
71
69
71
73
71
73
75
73
75
77
75
77
79
77
79
81
79
81
83
80
82
84
85
87
89
73
75
38.5
39.2
37.5
38.4
36.6
37.6
35.7
36.8
34.7
36.0
33.0
34.7
31.2
33.4
27.3
29.8
23.5
26.1
19.6
22.5
15.8
18.9