Installation/Wall Mounting - STEINEL IS 180-2 Installation Instructions Manual

Infrared sensor
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7

Installation/Wall mounting

Mains supply lead
Service lead
Note: The internal-corner
wall mount may be used
for mounting the sensor to
the wall. The cables can
be conveniently routed
down the surface of the
wall behind the unit and fed
through the cable entry.
Suppy cable
Surface wiring with wall mount
The site of installation
should be at least 50 cm
from a light because heat
radiated from it may trigger
the sensor unintentionally.
To obtain the specifi ed
ranges of 5/12 m, the
sensor should be installed
at a height of approx. 2 m.
Installation procedure:
1. Detach front cover
2. Release clip
and fl ip up
lower half of housing,
3. Mark drill holes, 4. Drill
the holes, insert wall plugs
(6 mm dia.), 5. Break open
cable entry for surface or
Concealed wiring
concealed wiring.
6. Feed through mains sup-
ply and service cable and
connect to terminals. Use
sealing plugs for surface
wiring.
a) Connect mains supply
lead
The mains supply leads is a
2 to 3-core cable:
L
= phase conductor
N
= neutral conductor
Surface wiring
PE = protective-earth
conductor
If you are in any doubt, you
must identify the cables
using a voltage tester; once
you have done so, discon-
nect the power supply
again. Connect the phase
(L) and neutral conductor
(N) to the clamp-type ter-
minal. Connect the protec-
tive earth conductor to the
earth terminal ( ).
A power ON/OFF switch
may of course be installed
in the power supply lead.
Alternatively, you may use
a normally closed contact
pushbutton to activate the
sensor manually for the
duration of the time setting.
– 14 –
b) Connect service lead
The service supply lead
to the light is also a 2 to
3-core cable. Connect the
light's current-carrying
conductor to the terminal
marked L'. The service lead
neutral conductor must be
connected to the terminal
marked N together with the
mains lead neutral conductor.
Installation using corner wall mount
,
Functions
Once you have connected
the unit to the mains power
supply, closed the housing
and fi tted the lens, you are
10 sec.-15. min.
2 - 2000 lux
Connect the protective-
10. Locate front cover
earth conductor to the
and fi t security screw
earth contact (
).
protect cover from unau-
7. Screw on housing
thorised removal.
and close again.
Important: Reversing the
8. Fit lens (set reach to
connections may result in
either 5 m or 12 m max),
damage to the unit.
see 'Reach setting' section.
9. Select time
and light
threshold setting
(see
'Functions' section).
The corner wall mount
enclosed with the unit pro-
vides a convenient means
of installing the IS 180-2
to internal and external
corners. Use the corner wall
holder as a template for
drilling the hole. This way,
you will drill the hole at the
right angle, allowing you to
fi t the wall mount with ease.
ready to put the system
Important: Only carry out
time and light threshold
into operation. Two setting
controls are concealed
settings with the lens fi tted.
behind the front cover
.
Switch-off delay
ment screw fully clockwise
(time setting)
the longest time of approx.
15 min. The shortest time
The chosen light ON time
setting is recommended
can be varied continuously
for setting the detection
from approx. 10 sec. to a
zone and performing the
maximum of 15 min. Turning
walk test.
the adjustment screw fully
anti-clockwise selects the
shortest time of approx.
10 sec., turning the adjust-
Twilight setting
the adjustment screw fully
(response threshold)
clockwise selects twilight
operation at approx. 2 lux.
The chosen detector
The adjustment screw
response threshold can be
must be turned fully
adjusted continuously from
anti-clockwise for setting
approx. 2 lux to 2000 lux.
the detection zone and
Turning the adjustment
performing the walk test in
screw fully anti-clockwise
daylight.
selects daylight operation
at approx. 2000 lux. Turning
– 15 –
to