Installation Instructions - STEINEL IS 180-2 Installation Instructions Manual

Infrared sensor
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7

Installation instructions

Dear Customer,
tured, tested and packed
with the greatest care.
Congratulations on purchas-
Please familiarise yourself
ing this STEINEL Infrared
with these instructions
Sensor and thank you for
before attempting to install
the confi dence you have
the sensor since prolonged
shown in us. You have cho-
reliable and trouble-free op-
sen a high-quality product
eration will only be ensured
that has been manufac-
System components
Security screw
Light threshold setting
control 2 – 2000 lux
Front cover
Time setting control
Lens (can be removed
10 sec. – 15 min.
and turned for selecting
the max. basic reach set-
tings of 5 m or 12 m)
Technical specifi cations
Dimensions:
(H x W x D) 120 x 76 x 56 mm
Output:
Filament bulbs, 1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max., at cos ϕ = 0.5,
inductive load at 230 V AC
6 x 58 W each max., C ≤ 132 μF
operating on 230 V AC
Connection:
230 – 240 V, 50 Hz
Detection angle
180° horizontal, 90° vertical
Sensor reach:
basic setting 1: 5 m max.
basic setting 2: 12 m max. (factory setting)
+ precision adjustment from 1 – 12 m by means
of clip-on shrouds
Time setting:
10 sec. – 15 min. (factory setting: 10 sec.)
Light threshold:
2 – 2000 lux (factory setting: 2000 lux)
Enclosure:
IP 54
*1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast (total capacity of all connected
ballasts below the value specifi ed).
if it is installed properly.
We hope your new Infrared
Sensor will give you lasting
satisfaction.
Clip (housing can be
fl ipped up for assembly
and connection to mains
power supply)
*1)
– 12 –
Principle
The IS 180-2 is equipped
detected through obstacles,
with two 120° pyro sensors
such as walls or panes of
which detect the invisible
glass. Heat radiation of this
heat emitted by moving
type will, therefore, not trig-
objects (people, animals
ger the sensor. With a 90°
etc.). The heat detected
angle of aperture, the two
is electronically converted
pyro sensors cover a detec-
into a signal that switches
tion angle of 180°. The lens
on loads (e.g. a light) con-
can be removed and turned,
nected to it. Heat is not
thereby permitting two max.
Reach max. 12 m
Reach max. 5 m
Direction of approach:
Direction of approach:
towards the sensor
across the detection zone
Safety warnings
a
a
Installation of the sensor
Disconnect the power
involves work on the
before attempting any
mains power supply.
work on the motion
This work must therefore
detector.
a
be carried out profes-
The electrical connec-
sionally in accordance
tion lead must be dead
with the applicable wiring
during installation.
regulations and supply
Therefore, switch off the
conditions.
power supply fi rst and
a
check that the circuit is
Please note that the sen-
disconnected using a
sor must be protected
voltage tester.
by a 10 A circuit breaker.
basic reach settings of 5 m
or 12 m. Using the wall
mounts provided with the
unit, the infrared sensor can
easily be fi tted to internal
and external corners.
Important: The most
reliable way of detecting
motion is to install the unit
so that the sensor is aimed
across the direction in
which a person would walk
and by ensuring that no
obstacles (such as trees,
walls etc.) obstruct the line
of sensor vision.
The mains supply lead
must be no greater than
10 mm in diameter.
a
Only carry out time and
light threshold settings
with the lens fi tted.
– 13 –