*Assembly instruction of an ellipse gear
1. .Put the grease(WEP001W8927) on the intermediate gear shaft and insert it in the center hole of
the intermediate gear block. And attach the Plate type spring through the intermediate gear shaft
as shown in figure.
2. Match the "V" shape of two ellipse gear on the intermediate gear block and drive pipe.
3. Assemble this block into the Gear box A as they have matched. And insert the intermediate gear
shaft of intermediate gear block into the groove A of Gear box A.
**When aligning two ellipse gears, smooth rotation will not be possible even if the alignment is off by
just one tooth. During rotation, the gears will not match up, and may cause the massager to lock. Correct
alignment of twogears required.