4. OPERATION; DISPLAY FUNCTIONS AND SETTING

4-1. Operator interface

This section provides an overview of the operation of the EXA operator interface. The basic procedures
for obtaining access to the three levels of operation are described briefly. For a step-by-step guide to
data entry, refer to the relevant section of this user's manual. Figure 4-1 shows the EXA operator inter-
face.
LEVEL 1: Maintenance
These functions are accessible by pushbutton through a flexible front cover window. The functions make
up the normal day-to-day operations that an operator may be required to complete. Adjustment of the
display and routine calibration are among the features accessible in this way. (See table 4-1).
LEVEL 2: Commissioning
A second menu is exposed when the EXA front cover is removed and the display board is revealed.
Users gain access to this menu by pressing the button marked
This menu is used to set such values as the output ranges and hold features. It also gives access to the
service menu. (See table 4-1).
LEVEL 3: Service
For more advanced configuration selections, press the button marked
until you reach SERVICE. Now push the "YES" button. Selecting and entering "Service Code" num-
bers in the commissioning menu provide access to the more advanced functions. An explanation of the
Service Codes is listed in chapter 5 and an overview table is shown in chapter 11.
Table 4-1. Operations overview
Maintenance
mA
mA
Commissioning
Service
(Access to coded entries
from the commissioning level)
NOTE:
All three levels may be separately protected by a password. See Service Code 52 in chapter 5
Service Code table for details on setting passwords.
Can operate with front panel shut
Measurement Mode
MODE key
Maintenande Mode
CALIB(ration)
NO key
DISP.1
NO key
DISP.2
NO key
HOLD
NO key
· Select desired mode and press YES
· The MODE key is used as a "Cancel and Return to Measurement Mode" escape key
Routine
CALIB
DISP. 1, 2
HOLD
*OUTP
*HOLD
*TEMP. 1, 2
*SERV
in the lower right of the display board.
*
*
Need to open front panel cover to operate
* key
Commissioning Mode
*OUTP Output Range Setting
*HOLD HOLD Settting
*TEMP.1 Temperature Setting
*TEMP.2 Temperature Setting
Service Mode
*SERV Service Mode
Function
Calibration with a standard solution or sample
Read auxiliary data or set message display
Switch hold on/off (when activated)
Adjust the output range
Activate the hold function
Select method of temperature compensation
Fine tune the specialized functions of the transmitter
Operation 4-1
, then press "NO" repeatedly
NO key
NO key
NO key
NO key
NO key
IM 12D08B02-01E
Chapter
6
4
5
5
5
5
5