Command Conventions; Common Parameter Values; Table 1: Parameter Conventions; Table 2: Parameter Descriptions - D-Link DWS-4000 Series Cli Command Reference

Hide thumbs Also See for DWS-4000 Series:
Table of Contents

Advertisement

D-Link Unified Switch CLI Command Reference
C
C
OMMAND
ONVENTIONS
In this document, the command name is in bold font. Parameters are in italic font. You must replace the parameter
name with an appropriate value, which might be a name or number. Parameters are order dependent.
The parameters for a command might include mandatory values, optional values, or keyword choices.
conventions this document uses to distinguish between value types.
Symbol
Example
<> angle brackets
<value>
[] square brackets
[value]
{} curly braces
{choice1 | choice2}
| Vertical bars
choice1 | choice2
[{}] Braces within
[{choice1 | choice2}]
square brackets
C
P
OMMON
ARAMETER
Parameter values might be names (strings) or numbers.To use spaces as part of a name parameter, enclose the name value
in double quotes. For example, the expression "System Name with Spaces" forces the system to accept the spaces. Empty
strings ("") are not valid user-defined strings.
Parameter
ipaddr
Interface or
slot/port
Logical Interface
Character strings
© 2009 D-Link Corporation. All Rights Reserved
4

Table 1: Parameter Conventions

V
ALUES
Table 2
describes common parameter values and value formatting.

Table 2: Parameter Descriptions

Description
This parameter is a valid IP address. You can enter the IP address in the following formats:
a (32 bits)
a.b (8.24 bits)
a.b.c (8.8.16 bits)
a.b.c.d (8.8.8.8)
In addition to these formats, the CLI accepts decimal, hexadecimal and octal formats through
the following input formats (where n is any valid hexadecimal, octal or decimal number):
0xn (CLI assumes hexadecimal format.)
0n (CLI assumes octal format with leading zeros.)
n (CLI assumes decimal format.)
Valid slot and port number separated by a forward slash. For example, 0/1 represents unit
number 0 and port number 1.
Represents a logical slot and port number. This is applicable in the case of a port-channel
(LAG). You can use the logical slot/port to configure the port-channel.
Use double quotation marks to identify character strings, for example, "System Name with
Spaces". An empty string ("") is not valid.
Description
Indicates that you must enter a value in place of the brackets and
text inside them.
Indicates an optional parameter that you can enter in place of the
brackets and text inside them.
Indicates that you must select a parameter from the list of choices.
Separates the mutually exclusive choices.
Indicates a choice within an optional element.
Table 1
describes the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwl-8600ap

Table of Contents