Mounting Plate; Digibar V (Optional); Power Supply; Possible Configurations Of The Mb1 - Teledyne MB1 Hardware Manual

Table of Contents

Advertisement

MB1
User Manual
This is a specially constructed cable for MB1, terminated at the wet end (sonar end) with an Impulse Titan
series connector, and at the RTA end with an Amphenol connector. Replacement part number 2313-
0100-0000.
2.5

Mounting Plate

This prefabricated stainless steel plate can be used as a generic mounting arrangement for most over the
side mounts.
2.6

Digibar V (optional)

The Digibar V is an instrument that determines sound velocity at a fixed point. This sound velocity is
used by the MB1 software in calculating the receive beams of the multibeam, and is required for correct
use of the system. A different real time sound velocity probe may be used and interfaced to the RTA
using the SVP port, providing the AML sentence can be output.
2.7

Power Supply

This is a recommended 100-240V A/C power supply with an output of 24V at 100W. This may be used to
power the sounder through the RTA. Alternatively a DC power cable can be supplied (Part number:
CABLEPOWDC) by Odom when required.
2.8

Possible Configurations of the MB1

The MB1 can be used as a standalone sonar as part of a pre existing suite of other sensors (Motion,
Heading, Position etc.) or has configurable options.
The options that may be added to the system are an internal GPS & Heading board (Hemisphere H320
model), TSS DMS525 motion sensor and the Digibar V real time sound velocity probe. Any of these
inputs can be configured to either be external (input to either the RTA or sonar head) or internal as fitted
to the equipment. The table below shows the possible configurations.
MB1 with optional Digibar V sound velocity probe attached
Page 7 of 37
 
7/6/12 

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents