Specifications - Secura Key SK-ACPE User & Installation Manual

A highly sophisticated, yet simple to use, two door access control unit with built-in ethernet communications
Table of Contents

Advertisement

SK-ACPe
PHYSICAL
POWER REQUIREMENTS
BACK-UP BATTERY
CARD READERS
SOFTWARE
OUTPUTS - 2 Per Door (Total of 4)
INPUTS - 2 Per Door (Total of 4)
COMMUNICATION
ENVIRONMENT
OPERATIONAL
This product complies with UL 294 Standards, CE (European Standards), and with Part 15 of Class B FCC Rules.
InStAllAtIon & oPerAtIng MAnuAl

SPECIFICATIONS

SK-ACPE-LE
Depth
Width
Height
Weight
Housing Material is All Steel; Color is Beige
16.5-24VAC (50-60 HZ), 40 VA or 16-30 VDC, 500 mA
If RK-WL readers are used, recommend a 16.5-24 VAC 40 VA transformer.
A 12 VDC Power Supply may be used if connected to Battery Back-Up Leads.
12 V, 4 Ah (Optional, Sold Separately)
Connect two card readers with two-line Wiegand output, up to 40 bits. While the Card Data
Format can vary, the Card ID bit length should not exceed 16 bits, which provides a maximum
Card ID of 65,535. Provides 14 VDC, 400 mA max. power for each card reader.
SK-NET
Software
TM
Latch & Alarm Shunt
Auxiliary
Auxiliary 1
Auxiliary 2
RS-232
RS-485
Wiegand Input (2)
Modem
Printer
Ambient Temperature
Humidity
Card Capacity
Time Zones
Facility Code
Latch/Alarm Shunt Timer
Antipassback
Auxiliary Inputs (2 Per Door)
Auxiliary Output (1 Per Door)
Limited Use Cards
Transaction Storage
Memory
3.0"
(7.62 cm)
10.0"
(25.40 cm)
11.0"
(27.94 cm)
68.8 oz. (1.95 kg)
Version 3x or greater
DPDT contact, 5A, up to 250 VAC or 30 VDC
DPDT contact, 2A, up to 220 VAC or 30 VDC
Requires SPST contact closure
Requires SPST contact closure
5-Wire Shielded Cable
Single Twisted Pair, shielded cable with a signal ground
Programmable up to 40 bits
14 VDC @ 400 mA supplied to each reader,
Requires Hayes compatible - 1.2 to 38.4k baud
Serial Printer (or Parallel printer with serial converter)
-40° F to 158° F (-40° C to 70° C)
0% to 95% relative humidity (non-condensing)
65,535 (Highest card number = 65,535)
15 for card access, one door unlock; full week plus
holiday in one-half hour segments; 32 programmable
holidays; selectable automatic daylight saving time.
Up to 16 different codes simultaneously (max. # of cards 65,535)
Programmable from 1/4 to 30 seconds
Real or Timed (1 to 30 minutes); hard or soft
Programmable for door monitor, tamper monitor, remote
open, remote inactive, bell, arming circuit or user defined
Output is programmable to activate under one of many
possible alarm conditions, time zone or card violations.
65,535, programmable from 1-500 uses, days, weeks or
number of days after first use.
10,000 events
Non-volatile
B-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents