RM-82
RF troubleshooting
i
Check Save to Phone
ii Press Tune
iii Press Stop to store the data to the phone
Results
RX channel select filter calibration is finished.
RX calibration
Context
RX calibration is used to determine gain at different gain settings for front-end and the Helgo ASIC and it
needs to be done in all three bands.
Note:
Always calibrate band 900 first.
RX calibration requires an external signal generator.
Steps
1. Select Tuning→RX calibration
Issue 1
Figure 104 RX Channel Select Filter Calibration
COMPANY CONFIDENTIAL
Copyright © 2005 Nokia. All rights reserved.
Nokia Customer Care
Page 8 –7