Does Gsm Pa (N7502) Get Correct Det_Sw_G -Voltage From Vinku Asic (N7501); Are Components In Gsm Power Control Loop In Place And Working Ok - Nokia RM-57 Service Manual

Nokia 6681/6682 mobile terminal
Table of Contents

Advertisement

Appendix A: RF Troubleshooting
3.5.2.3 Replace Vinku (N7501)

3.5.3 Does GSM PA (N7502) get correct DET_SW_G -voltage from Vinku ASIC (N7501)?

GSM transmitter has to be active before DET_SW_G voltage can be measured. Procedure is
explained in section "Transmitter troubleshooting".
Measurement can be done with an oscilloscope and a probe.
Connect the probe to C7595. Notice: C7595 is a non-assembled component so the probe
should be connected to the pad that can be still found from the PWB.
DET_SW_G voltage should be about 2.8 V while TX burst and 0 V otherwise.
3.5.3.1 Replace Vinku (N7501)

3.5.4 Are components in GSM power control loop in place and working ok?

R7516 and C7559
Disconnect the power supply from the phone and use an ohmmeter to check that C7559 is
not short-circuited. If short-circuit is found replace the capacitor.
Check R7516 resistance value with an ohmmeter and replace resistor if needed.
A-70
Company Confidential
Copyright © 2005 Nokia. All rights reserved
Nokia Customer Care