Nokia Customer Care
8.
Click "Calculate Coefficients".
9.
Check that the coeffiecient values are within the limits specified in the following table.
GSM850/GSM900 EDGE off
PL5 coefficient
PL15 coefficient
PL19 coefficient
GSM850/GSM900 EDGE on
PL8 coefficient
PL15 coefficient
PL19 coefficient
GSM1800 EDGE off
PL0 coefficient
PL11 coefficient
PL15 coefficient
GSM1800 EDGE on
PL2 coefficient
PL11 coefficient
Page 7–36
Min
0.45
0.12
0.35
0.12
0.45
0.12
0.35
Company Confidential
Copyright ©2005 Nokia. All Rights Reserved.
RF Troubleshooting and Manual Tuning Guide
Typ
0.626
0.234
0.195
0.419
0.247
0.204
0.51
0.219
0.185
0.394
0.23
RM-57/58
Max
0.73
0.3
0.6
0.3
0.7
0.3
0.6
Issue 1