Section 4 - Component Access (Continued); Removing The Console - Whirlpool WED99HEDW0 Technical Education

Hybridcare duet dryer with heat pump technology
Table of Contents

Advertisement

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
To Remove the User Interface
1. Unplug dryer or disconnect power.
2. Perform the procedures on page 4-4, "Removing the Top
Panel" and "Removing the Console" prior to performing
the following steps.
3. Pull the cycle selector knob off the switch shaft (see Figure
1).
4. Disconnect the two (2) harnesses from the user interface
(see Figure 2).
5. Remove the eight (8) 1/4" hex-head screws securing the
user interface to the console as illustrated in Figure 3.
6. Separate user interface from console assembly.
Console
Harnesses
Removing the User Interface (UI)
Console Assembly
Disconnect
harnesses
REASSEMBLY NOTE: When reinstalling the user interface to
the console, only hand tighten the eight (8) hex-head screws
until snug. Using a power driver will strip the screw holes and
stress the capacitive touch user interface.
User Interface
Figure 3
HybridCare™ Dryer with Heat Pump Technology
COMPONENT ACCESS
Remove
selector knob
Figure 1
Figure 2
n
4-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wed99hedc0

Table of Contents