COMPONENT ACCESS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
To Remove the Top Panel
1. Unplug dryer or disconnect power.
2. Remove the two (2) 1/4" hex-head screws from the top
panel as illustrated in Figure 1.
Top Panel Screws
3. Lift the rear of the top panel, pull back, and remove top
panel from the dryer.
4-4
HybridCare™ Dryer with Heat Pump Technology
n
Removing the Top Panel & Console
Figure 1
To Remove the Console
1. After removing the top panel, remove connector P2 from
the CCU and disconnect the in-line connector between
the UI and drum light (see Figure 2).
Drum Light Connector
P2 Connector
2. Remove the two (2) 1/4" hex head screws securing the
console to the cabinet (see Figure 3).
Console Screws
3. Lift up on console and pull out to remove from dryer.
Figure 2
Figure 3