Majestic MDVI30IN Installation Manual page 17

Ruby series
Hide thumbs Also See for MDVI30IN:
Table of Contents

Advertisement

To prevent odors and cold air drafts, it may be necessary to
place non-combustible insulation or fi eld fabricated metal
plates around the vent pipe fl ues as they go through the
damper.
Note: The LINK-DV4-30B and LINKSQ-DV4-30 systems
REQUIRE this insulation.
Masonry
LINK-DV30B
LINKSQ-DV30
Installation*
TERMINATION
EXHAUST
AIR
VENT PIPE
INLET AIR
VENT PIPE
*LINK-DV30B/LINKSQ-DV30: This installation may perform better
and allow less cold air infi ltration in negative pressure settings.
**LINK-DV430B/LINKSQ-DV4-30:
• This installation may be more susceptible to cold air infi ltration and
the effects of negative pressure on the appliance's performance.
• Depending on the chimney cleanliness, consider using the
full length intake so as to lessen the possibility of sense rod
contamination and fl ame rectifi cation issues.
Figure 7.6
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. H • 12/16
LINK-DV4-30B
LINKSQ-DV4-30
Installation**
CAP
EXHAUST
AIR
VENT PIPE
OR
Factory Built
Wood Burning
OPTIONAL LINK-ZC-ADPB
FOR USE WITH CLASS A
WARNING:
DO NOT BLOCK
THIS PIPE END!
Note: Untwist the
pipe while extend-
ing it, to achieve full
30' length.
Remove 18 inch x 18 inch fl ashing on cap by removing 3
INLET AIR
screws. Connect both the LINK-ZC-ADPB to Class A Pipe
VENT PIPE
and the termination cap to the LINK-ZC-ADPB with the
self tapping screws provided.
WOODBURNING PIPE
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mdvi35inMdvi35ilMdvi30il

Table of Contents