Ice Chute Maintenance

IMPORTANT: Perform the following daily.
NOTE: The ice chute has a built in safety
feature which disables the unit when the ice
chute cover is removed. If the ice chute
cover is not properly installed, the agitator
and ice chute gate will not function.
1.
Press and hold the "P" and "UP" buttons
for five (5) seconds to enter purge mode.
LED displays "Purg".
2.
Holding a large container or bucket
beneath the ice chute, press and hold the
"Manual" button to open the ice gate. Gate
stays open as long as the button is
depressed.
3.
Press and hold the "P" button for five (5)
seconds to exit the purge mode.
4.
Remove the finger guard from the ice
chute cover by sliding the guard upward
then out.
5.
Remove the ice chute cover from the ice
chute by pushing the black locking tab
(Figure 4) back and sliding the ice chute
upward and out.
6.
Wash the ice chute, ice chute cover, finger
guard, and ice level flapper with a nylon
bristle brush and a clean rag using the
soap solution.
7.
Rinse the parts with clean potable water
then rinse with sanitizing solution. Allow all
parts to air dry.
8.
Replace the ice chute and slide down into
place.
9.
If the agitator or ice chute are not working,
remove the ice chute cover and replace it.
10.
Reinstall the finger guard onto the ice
chute cover.
11.
If ERR is displayed, press "M" button to
return to dispense mode.
Publication Number: 621054211OPR
Ice Chute
Finger
Guard
- 6 -
Tower Cover
Auger Transition
Cap
Ice Chute Cover
Figure 3