Loc (Lock); Fill; Err (Error); Flap (Flapper) - Cornelius STARBUCKS UC100 PROGATE Operator's Manual

Hide thumbs Also See for STARBUCKS UC100 PROGATE:
Table of Contents

Advertisement

LOC (Lock)

When displayed, check to make sure that ice bin covers, ice chute transition, piece ice flapper and ice
chute are attached properly. Once secured, push the "M" button on the keypad to return to dispense
mode.

FILL

When displayed, all ice has been consumed and needs to be replaced. Refill the ice bin. Close all ice bin
covers and push the "M" button on the keypad to return to dispense mode.

ERR (Error)

When displayed, a system fault has occurred. Push the "M" button on the keypad to reset the dispenser
and return to dispense mode.

FLAP (Flapper)

This code is displayed when the flapper has not made contact or not made correct contact with the
microswitch. Push the "M" button on the keypad to return to the dispense mode.

E01

Keypad pc board has failed its internal memory check. Call service.

E02

A keypad button has been held down or stuck for one minute. Push the "M" button on the keypad to
return to dispense mode.
S
-
O
TART
UP AND
Fill the hopper with ice and then push one of the "V" buttons on the keypad to dispense a large cup of ice.
Repeat this procedure every time the dispenser has run out of ice. This insures that the ice chute is
completely filled before use. If the dispenser fails to dispense ice, see troubleshooting guide.
CAUTION: Use caution to avoid spilling ice when filling the dispenser. Clean up any spilled
ice immediately. To prevent contamination of ice, the lid must be installed on the unit at all
times.

Programming the Ice Weight Portion

The ice weight portion setting is factory set for each portion size or keypad button. Follow the instructions
below to increase or decrease the amount of ice dispensed for a portion size.
1.
Press "P" and Blended Short (S) buttons simultaneously until SIZE displays on the information
display.
2.
Press and hold the desired size you wish to program until corresponding green LED flashes.
NOTE: The information display will now show the current value (in milliseconds) of that portion
size.
3.
Press the up or down button to increase/decrease the duration of dispense. Each press increases/
decreases the duration by 1ms.
4.
Press the corresponding size button currently being programed until the green LED stops flashing.
5.
To save the new programmed size, press the "P" and the Blended Short (S) buttons simultaneously
until the screen clears. If no action is taken within 60 seconds, dispense mode resumes and any
changes are not saved.
Viewing & Resetting Defaults:
The controller has four default tables contained within it. These tables are: "USA", "International",
"Custom" and "Data".
To view or program the current table perform the following steps:
1.
Press and hold the "P" button and the "M" button simultaneously.
© 2008-2014, Cornelius Inc.
I
PERATING
NSTRUCTIONS
UC100 ProGate Operator's Manual
- 3 -
Publication Number: 621054211OPR

Advertisement

Table of Contents
loading