Table Glass; Slit Glass (Spf Scan Mode) - Sharp AR-M550N Service Manual

Hide thumbs Also See for AR-M550N:
Table of Contents

Advertisement

: Feb. 6 2004
1
7) Remove the tray.
8) Remove the left side cabinets front and rear.
9) Remove the screw.
10) Hold the both sides of the scanner base, and slide it toward you to
remove.
1
AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 95
a-1. Table glass
a-2. Slit glass (SPF scan mode)
(When executing internal maintenance of the scanner)
1) Loosen the screws in the hinge section, and lower the two metal
fixtures.
2) Open the SPF, and slide the SPF drop-preventing stopper pin of
the Hinge L to the drop preventing position.
3) Remove the right glass holder.
NOTE: When assembling or disassembling the table glass, check that
1
the glass does not cover the steel plate on the front side.
4) Using a cloth, etc. on the right glass surface to prevent fingerprints,
remove the cover.
5) Remove the white reference glass unit.