: Feb. 6 2004
1
(2) Maintenance and parts replacement
(Replacement parts)
No.
Unit
a
1

CIS control PWB/CIS unit

a-1
a-1. CIS control PWB/CIS unit
1) Remove the cabinet. (See "a-1. Cabinet" in the previous section,
"[External outfit section]")
2) Remove the document tray unit. (See "a. Document tray unit" in
the previous section, "[Paper feed tray section]")
3) Remove the harness, then remove the PWB cover.
4) Remove each cable, and remove the PWB.
5) Loosen the hinge screws to lower the two fittings.
Parts
AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 126
6) Open the SPF, attach the SPF drop preventing stopper, and
1
remove the paper guide.
7) Remove the ground lead and CIS.

Caution when assembling

• When assembling the flat cable, first attach the lower side then the
upper side.
1
BLUE
1
• Clean the both surfaces of the paper guide glass.
CIS cnt PWB