3) Remove the soft NIC PWB unit.
4) Remove the soft NIC PWB angle from the soft NIC PWB.
AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 150
a-9. MFP FLASH ROM PWB
1) Pull out the NIC control unit. (See "a-8. Soft NIC PWB" in this sec-
tion)
2) Release the lock, and remove the MFP Flash PWB.
a-10. MFP controller PWB
1) Remove the manual feed cover F, the right cabinet middle, and the
right cabinet upper. (See "a-8. Soft NIC PWB" in this section)
2) Pull out the NIC control unit, and remove the flat cable. Release
the lock, and remove the NIC control unit.
3) Remove the Soft NIC PWB unit.
4) Remove the PWB protection plate. Remove the MFP controller
PWB.