Specifications - Panasonic KX-TVS50 Installation Manual

Voice processing system
Hide thumbs Also See for KX-TVS50:
Table of Contents

Advertisement

7.5 SPECIFICATIONS

7.5 SPECIFICATIONS
Port:
Dialing Method:
Flash Time:
CPC Detection
Type of Line:
Extension Numbering:
Pause Time:
Message Waiting Lamp:
Main CPU:
Capacity for Flash Memory:
Number of Mailboxes:
Number of Messages:
Personal Greeting Message Length:
Message Retention Time:
Maximum Message Length:
Reports:
Connections
Telephone Line:
Data Port:
Environmental Requirements:
Power Source:
Power Consumption:
162
Table 31
2 Digital/Analog ports
DTMF/Pulse (10/20 pps)
100/300/600/900 ms (programmable)
6.5/150/300/450/600 ms (programmable)
Loop start minimum Loop Current: 20 mA
minimum Line Voltage: 7 V DC
minimum Ringing Voltage: 40 V AC
2 to 5 digits (programmable)
1 to 9 s (programmable)
Programmable DTMF sequence.
16-bit microprocessor
TVS50: 2 h (expandable)
TVS80: 6 h (non-expandable)
TVS50: Max. 32
TVS80: Max. 64
(including System Manager and Message Manager
mailboxes)
Max. 100 per mailbox (programmable)
8 to 60 s (programmable)
1 to 30 days or unlimited (programmable)
1 to 6 min (programmable)
Mailbox Assignment, COS (Class of Service) Assignment,
System Service Report, Call Account Report, Port Usage
Report, Flash Memory Usage Report, Mailbox Usage
Report, FAX Call Report
Modular connectors
2
In case of Inband, 2-conductor wire
In case of APT, 4-conductor wire with APT interface
In case of DPT, 4-conductor wire with DPT interface
RS-232C interface port
0 - 40 °C {32 - 104 °F}, 10 - 90 % relative humidity
120 V AC, 60 Hz
Approx. 10 W
SYSTEM MAINTENANCE AND TROUBLESHOOTING
2
2
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tvs80

Table of Contents